General safety precautions for metallographic inlay machines

来源:QMAXIS 日期:2022-07-06 11:10:41 浏览量:608
返回列表

Below: Single tube fully automatic hot press inlay machine (left), double tube fully automatic hot press inlay machine (right)

 镶嵌机

Choosing suitable and representative samples is an important step in conducting metallographic and microscopic analysis, but some sample sizes and shapes may not be very regular. At this point, our metallographic inlay machine will come in handy and can be used for inlaying.


The metallographic inlay machine is very suitable for hot pressing and inlaying small metallographic samples that are not plastic, difficult to take, and are not easy to take. After forming, it is very convenient to perform sample polishing and polishing operations, which is also helpful for microstructure determination under a metallographic microscope. The automatic inlay machine uses inlay powder for inlay. Pour the sample and inlay powder into the inlay machine at room temperature, heat and pressurize them, and solidify them into standard size samples after 5-10 minutes, which is very simple and convenient. The standard size sample is more conducive to polishing and polishing the sample.


Precautions for using automatic metallographic inlay machine:


1. The equipment grounding must be good and single-phase three-pole standard power sockets must be used.


2. The mounting machine should be installed on a stable and vibration free workbench, with an ambient temperature of 10-30 degrees Celsius and a relative humidity of less than 85%. There should be no corrosive gases or conductive dust around.


3. The upper cover plate and the top of the equipment have a certain temperature, so it is important to avoid burns during use.


4. After installation, it is necessary to carefully train and read the user manual. If a malfunction occurs, maintenance operations must be carried out by professional and trained personnel.


5. When used for the first time, a small amount of smoke may be generated, which is a relatively normal phenomenon. But there will definitely be no open flames.


For other professional knowledge related to metallographic sampling, please visit the official website www.qmaxis.cn for technical exchange with Kemai's engineers, or visit Kemai Testing Nanjing Laboratory for on-site testing.